If you are responsible for facility electrical operations, you may have heard of the recent updates to IEEE 1584 “IEEE Guide for Performing Arc-Flash Hazard Calculations.” The previous major edition of the standard was in 2002, and many changes have been made in the 2018 version.
 more

The current approach in building design focuses almost solely on increasing energy efficiency by improving system-oriented controls and behavior. However, occupant behavior also affects energy efficiency. To provide a more realistic modeling result, occupant behavior needs to be included in energy modeling.  more

Micro-electro-mechanical systems (MEMS) were invented in the second half of the past century and since then their use has been growing rapidly. The automobile industry was an early adopter, using MEMS sensors for automobile navigation, tire pressure control, and airbag deployment. As we start transitioning from today’s buildings and systems to future smart buildings, design engineers will have a wide variety of MEMS applications to choose from. more

In my earlier columns, I tried to explain the concept of uncertainty analysis and also draw the attention of the industry to the advantages of performing probabilistic energy modeling. One of the most valuable complementary tools to uncertainty analysis is sensitivity analysis. Terje Aven in his book, Foundation of Risk Analysis,1 gives the following definition for sensitivity analysis: “A sensitivity analysis is a study of how sensitive the risk is with respect to changes in input parameter of risk model.” more

Health-care design evolves constantly, reflecting improvements and advancements in surgical techniques, equipment (such as MRIs and robotic surgical equipment), clinical practices, hospital design trends, energy efficiency, sustainable design, and other factors. Ventilation for health-care facilities must change to be aligned with the changing needs of health-care facilities design, patients, surgeons, clinical staff, and visitors. more

Building an energy-efficient building often begins with an energy (cost) comparison between a design building and an imaginary baseline building as defined in ASHRAE/IES Standard 90.1, Appendix G. Even though this method has contributed to higher performance of buildings and systems, I believe we can do better than that. more

When one thinks of critical infrastructures, some come quickly to mind: the water system, the power grid, the Internet, dams, bridges, roads, air and rail transportation to name a few. Commercial buildings may not occur to the average individual as critical infrastructure, but they are considered as such by the Department of Homeland Security (DHS) and ASIS International. If we think about the impact of the 9/11 attack on the Twin Towers, we understand why. The attack on the Twin Towers cost nearly 2,600 people their lives, and launched the United States into a long term war on terror that has increased the national debt approximately 1.5 trillion dollars.1  more

In my November column, I discussed the necessity of performing a probabilistic energy modeling process instead of a deterministic one for an ASHRAE/IES Standard 90.1, Appendix G, design building. To be able to run a probabilistic energy model, the first step is to develop a tolerance margin library for all the construction material that would be used in constructing a building and for its associated equipment. more

Uncertainty analysis is the process of changing simulation model input parameters in a small margin of possible occurrences and observing how simulation output can be affected (output probability distribution). That is the basic difference between a deterministic simulation and a probabilistic (uncertain) simulation. Uncertainty analysis is a strong tool for modelers and those who use modeling results to make well-informed decisions. more

Most HVAC design engineers use an array of sophisticated software calculation and modeling tools for load calculations and energy analysis. These tools offer almost total flexibility for the engineer to define physical arrangement, thermal parameters, operating schedules, internal loads and zoning. To achieve that flexibility, the input parameters are extensive and time consuming. more